Contact us

HTY-AW01-MC

Water Activity Meter

Water activity meter AW01-MC is based on the mirror condensation dew point method.

Widely used in pharmaceuticals, food, and other fields to ensure that the risk of microbial contamination in products is controllable.

High measurement accuracy:±0.003aw

Validation and calibration: Inexpensive consumables, no need for tedious and time-consuming sensor calibration

Fast testing speed: rapid and precise temperature control, reducing testing time to within 4 minutes

Features

Working Principle:

The dew point temperature is determined by cooling a mirror in the sample chamber until condensation occurs and recording the mirror temperature at that point. The saturated vapor pressure (P) can be obtained from a table using this dew point temperature. The ratio of this saturated vapor pressure (P) to the saturated vapor pressure (P0) of pure water is the water activity (aw=P/P0).

 

  • Mirror Condensation Method: Traceable to international/national basic methods, traceable to the international basic measurement units (SI units)”United States Pharmacopoeia'<1112>recommended methods.
  • Strong Storage Capacity:  Records test temperature, time, and sample information, and can store data for more than 10 years.
  • High Accuracy: ±0.003aw, making the instrument more accurate.
  • Data Integrity: Compliant with 21CFR part 11, 3-level user access, audit trails, and various forms of backup.
  • Low Maintenance Cost: Cheap consumables and no need for cumbersome and time-consuming sensor calibration.
  • Fast Test Speed:  Standard equipped with active temperature control module, fast and precise temperature control, shortening detection time to within 6 minutes.

Specifications

Test Range: (0.030-1.000)aw
Max. Allowable Error: ±0.003aw
Resolution: ±0.0001aw
Repeatability Error: ≤3%
Test Time: 6-8min
Temperature Control Range: (10-50)℃
Temperature Control Accuracy: ±0.2℃
Environment: Temperature (4-50)℃, (10%-85%)RH (non-condensing)
Sample Temperature: (10-50)℃ accuracy ±0.2℃, resolution 0.01℃
Input Power: (100~240)±10%VAC, 50/60Hz
Power: ≤100W
Sample Cup Capacity: 7mL
Data Storage: More than ten years of storage period (depending on the size of the memory, each group includes water activity, temperature, time, date, operator and sensor type)

Compliance

  • USP 922 Water Activity
  • USP 1112 Application of Water Activity Determination in Non-sterile Drugs
  • USP 1241 Water-Solid Interactions in Drug Systems

Applications

It can be used in the pharmaceutical, food, and biodegradable industries to test drugs, food, soil, compost, etc.

Pharmaceuticals

Food industry

Cosmetics industry

Send Inquiry

Article

News

18/12/2025

A New Chapter in Advanced Materials: Tailin Celebrates Groundbreaking of Strategic Production Base

News

17/12/2025

The Final Guardian of Drug Safety: Ensuring Reliable Vials Sealing and Security

News

21/11/2025

From FDA Warning Letters to New Pharmacopoeia Standards: Where Are the Boundaries of “Complete” Microbial Data?

News

04/11/2025

Tailin Honored as “Advanced Committee Unit for Standardization Work” for Supporting Domestic & International Sterilization Standardization

EN

CN

Reserve Event

Event:

Date and time:

30 June - 2 July 2026 09:00am - 18:00pm

Add:

KoelnMesse Halls 7+8, Cologne, Germany

Booth:

Hall 7, N21

Reservation Form

Reserve Event

Event:

Date and time:

16-18 June 2026 09:00am - 18:00pm

Add:

Shanghai New International Expo Center, Shanghai, China

Booth:

N3B56

Reservation Form

Reserve Event

Event:

Date and time:

21-23 April 2026 09:00am - 17:00pm

Add:

Algiers exhibition center – SAFEX (Central Hall)

Booth:

B04 (224)

Reservation Form