Contact us

Honeycomb Cell Culture System

Honeycomb Cell Culture System

Tailin honeycomb cell culture system is specially used for the cultivation of cell products. lt is a closed integrated operating system that meets the requirements of GMP aseptic production and provides a highly intelligent and continuous aseptic culture environment for cell products.

The system is equipped with a combination of a honeycomb cell culture incubator and a docking incubator to meet the requirements of large-scale and multi-sample cell culture.

Provides a constant temperature, high humidity, oxygen concentration, and carbon dioxide concentration that are conducive to cell growth

Provides a Class A clean environment for cell culture, meeting the GMP requirements

Supports multi-level authority management, enable data traceability

Features

  • Provide a Class A clean environment throughout the entire cell production and culture process, complying with GMP requirements.
  • Real-time recording and storage of system control and environmental monitoring data enable data traceability throughout theproduction and culture process.
  • The compact integrated design effectively saves space, eliminating the need for large building footprints.
  • Installation is only required in a Class D or higher clean environment, reducing high-level cleanrooms’ construction and operational costs.
  • Modular design, allowing flexible expansion of culture space to meet the requirements for simultaneous culture of large-scale and different batches of cells.
  • The visual culture process monitoring system can identify each independent culture unit and manage batches through monitoring, meeting the FDA 21 CFR Part 11 requirements for electronic records, electronic signatures, and audit trails.
  • It provides a highly secure sterile cell culture environment, utilizing hydrogen peroxide sterilization technology to achievemulti-dimensional sterilization protection for the incubator.
  • An integrated rapid sterilization station allows for individual sterilization of culture units.
  • Equipped with a docking incubator, it enables rapid and flexible docking between the incubator and the cell and gene therapy isolator, ensuring that the entire process from cell handling to culture is maintained in a sterile environment to prevent cross-contamination.

Specifications

Incubator Volume: 30L, 60L, 100L Temperature Setting Range: RT+5~50°C
Temperature Resolution: 0.1°C Temperature Display Error: ±0.1°C (at 37°C)
Temperature Control Error: ±0.2°C (at 37°C) Temperature Control Fluctuation: ±0.2°C (at 37°C)
Temperature Control Uniformity: ±0.3°C (at 37°C) Temperature Insulation: ≤8°C
RH: ≥90%RH CO2 Concentration Control Range: 0%~20%
CO2 Concentration Display Resolution: 0.10% CO2 Concentration Display Error: ±0.1% (concentration at 5%)
CO2 Concentration Control Error: ±0.3% (concentration at 5%) Leak Rate: ≤0.5% Vol/h, test pressure at 100Pa
Noise: ≤65dB(A) at working Power Supply: AC220V
Power of Each Incubator: 200-350W Data Management: Real-time data recording, data transfer with incubators
Alarm:
a. Temperature too high/too low alarm;
b. CO2 concentration too high/too low alarm;
c. Water pan water shortage alarm; d. Temperature sensor protection, CO2 concentration sensor failure, fan failure, etc.

Applications

Suitable for the cultivation of most engineered cell products on the market and used in large hospitals, cell research institutions, cell therapy companies, etc.

Cell Therapy Manufacturing

GMP Sterile Laboratories

Clinical & Research Centers

Send Inquiry

Article

News

18/12/2025

A New Chapter in Advanced Materials: Tailin Celebrates Groundbreaking of Strategic Production Base

News

17/12/2025

The Final Guardian of Drug Safety: Ensuring Reliable Vials Sealing and Security

News

21/11/2025

From FDA Warning Letters to New Pharmacopoeia Standards: Where Are the Boundaries of “Complete” Microbial Data?

News

04/11/2025

Tailin Honored as “Advanced Committee Unit for Standardization Work” for Supporting Domestic & International Sterilization Standardization

EN

CN

Reserve Event

Event:

Date and time:

30 June - 2 July 2026 09:00am - 18:00pm

Add:

KoelnMesse Halls 7+8, Cologne, Germany

Booth:

Hall 7, N21

Reservation Form

Reserve Event

Event:

Date and time:

16-18 June 2026 09:00am - 18:00pm

Add:

Shanghai New International Expo Center, Shanghai, China

Booth:

N3B56

Reservation Form

Reserve Event

Event:

Date and time:

21-23 April 2026 09:00am - 17:00pm

Add:

Algiers exhibition center – SAFEX (Central Hall)

Booth:

B04 (224)

Reservation Form