BIER-EO100

Biological Indicator Evaluation Resister

For testing the resistance of biological indicators for ethylene oxide, suitable for pharmaceutical and medical device manufacturers, food and drug regulatory authorities, third-party testing institutions, and other relevant fields.

One-click automatic water filling, sterilization, and exhaust

Data authority, traceability, and real-time observation

Safe and reliable

Features

  • Intelligent operation; one-click automatic water filling, sterilization, and exhaust.
  • Data authority, traceability, and real-time observation to verify or determine the sterilization situation.
  • Safe and reliable; door opening protection, automatic pressure relief, temperature grading, negative pressure airtightness test procedures, multi-level management authority settings.
  • High Stability.
  • Flexible adjustments to customize the program, one-click generation of the test report.

Specifications

Monitoring Method: Sensors from the US brand Sterilizer Concentration: 100~1200mg/L
Sterilization Temperature: 29℃~65℃ RH: 30%~80%
Pressure Range: 4~20kPa Concentration Rising Period: ≤10s
Management Authority: three levels of management authority with GMP management requirements Concentration Decline Period: ≤ 10s
Time to Vacuum: ≤ 60s Leakage Rate: ≤ 0.13kPa/min
Single Sterilization Quantity: 20 pcs Electronic Signature: Yes
Sterilization Curve: Yes Power Supply: 380VAC/50HZ
Power: 5KW Dimensions: 112 x183 x 105 (cm)
Weight: 700kg Test Report: Yes

Applications

Pharmaceuticals

Medical Industry

Biosafety Laboratoires

Send Inquiry

Article

News

18/12/2025

A New Chapter in Advanced Materials: Tailin Celebrates Groundbreaking of Strategic Production Base

News

17/12/2025

The Final Guardian of Drug Safety: Ensuring Reliable Vials Sealing and Security

News

21/11/2025

From FDA Warning Letters to New Pharmacopoeia Standards: Where Are the Boundaries of “Complete” Microbial Data?

News

04/11/2025

Tailin Honored as “Advanced Committee Unit for Standardization Work” for Supporting Domestic & International Sterilization Standardization

EN

CN

Reserve Event

Event:

Date and time:

30 June - 2 July 2026 09:00am - 18:00pm

Add:

KoelnMesse Halls 7+8, Cologne, Germany

Booth:

Hall 7, N21

Reservation Form

Reserve Event

Event:

Date and time:

16-18 June 2026 09:00am - 18:00pm

Add:

Shanghai New International Expo Center, Shanghai, China

Booth:

N3B56

Reservation Form

Reserve Event

Event:

Date and time:

21-23 April 2026 09:00am - 17:00pm

Add:

Algiers exhibition center – SAFEX (Central Hall)

Booth:

B04 (224)

Reservation Form