Contact us

GIT-WLAN03

Glove Integrity Tester

The GIT-WLAN03 is used to leak test gloves installed on isolators or RABS. It leverages wireless communication and intelligent software technologies to achieve wireless device communication, paperless data management, and in-situ testing. It supports multi-device group control and data interconnectivity, and it automatically generates GMP-compliant electronic test reports, building a closed-loop data ecosystem that runs through the entire process.

AI algorithm deeply integrated with glove characteristics

Visualized testing process

The glove integrity management system can simultaneously monitor multiple glove integrity testers online

Features

  • Temperature Monitoring
    • The high-precision temperature sensor provides an accuracy of ±0.1 in detecting temperature differences during testing.
  • Modular Design
    • The charging component module and internal battery pack can be easily disassembled and replaced.
    • The battery pack uses the internationally accepted standard 18650 battery.
    • Test port modules can be customized into different shapes and sizes according to customer need.
  • Glove No. Code
    • RFID chip technology automatically identifies the glove number and includes it in the test results.
  • Detection Accuracy
    • Leak rate detection limit can reach 100μm (under certain test parameters and test conditions).
  • Convenience
    • Equipped with a charging trolley for continuous use, a fully charged machine can run for ≥8h.
    • Overall lightweight design, total weight ≤ 2.5kg, one person can easily hold and operate.

Specifications

Temperature Monitoring Accuracy: ±0.1℃ Test Time: ≤6min
Smallest Detectable Hole: 100μm Continuous Working Time: ≥4 hours
Net Weight: ≤3Kgs Battery: 12V Lithium battery
Dimensions: Φ280x125mm *Glove flange interface can be customized

Compliance

ISO14644-7 Annex E.5

“The pressure decay tests described are only a few of many tests that can be used for glove testing and are intended to illustrate glove leak test procedures.”

 

EU GMP Annex 1 (2022) 4.21

“For isolators, leak testing of the glove system should be performed using a methodology demonstrated to be suitable for the task and criticality. The testing should be performed at defined intervals. ”

“For RABS… Gloves should be visually examined with each use, and integrity testing should be performed at periodic intervals.”

 

FDA Guidance for Industry: Sterile Drug Products Produced by Aseptic Processing (2004) Appendix 1

“…Physical integrity tests should also be performed routinely. A breach in glove integrity can be of serious consequence. …”

Applications

Pharmaceutical and Biotechnology Aseptic Production

Food Industry Safety Control

High-Risk Industrial Protection

FAQ

The GIT-WLAN03 requires each tester to log in individually, even in group-control mode. The central management software records the operator information for each device and binds it to the corresponding test data, ensuring precise data attribution and maintaining accuracy throughout the testing process.

Current glove integrity testing mainly uses the pressure decay method, but its accuracy is limited by sensitivity and interference, falling short of pharmaceutical standards. Tailin developed a novel leak detection algorithm based on glove deformation and pressure response. Using dual-control experiments and nonlinear regression, the system compares real-time test curves with reference curves, enabling precise detection of 100μm micropore leaks.

The tester performs fully automatic monitoring of glove and flange pressure variations during testing. Real-time data is displayed on the user interface and transmitted wirelessly to the monitoring system for centralized storage and analysis. Monitoring system supports multi-level permission groups.

Yes. The GIT-WLAN03 software meets 21 CFR Part 11 requirements for electronic records and e-signatures, includes multi-level user authority groups, and enforces a secure data review process. All test results are automatically logged and traceable for audit and validation purposes.

Send Inquiry

Article

News

18/12/2025

A New Chapter in Advanced Materials: Tailin Celebrates Groundbreaking of Strategic Production Base

News

17/12/2025

The Final Guardian of Drug Safety: Ensuring Reliable Vials Sealing and Security

News

21/11/2025

From FDA Warning Letters to New Pharmacopoeia Standards: Where Are the Boundaries of “Complete” Microbial Data?

News

04/11/2025

Tailin Honored as “Advanced Committee Unit for Standardization Work” for Supporting Domestic & International Sterilization Standardization

EN

CN

Reserve Event

Event:

Date and time:

30 June - 2 July 2026 09:00am - 18:00pm

Add:

KoelnMesse Halls 7+8, Cologne, Germany

Booth:

Hall 7, N21

Reservation Form

Reserve Event

Event:

Date and time:

16-18 June 2026 09:00am - 18:00pm

Add:

Shanghai New International Expo Center, Shanghai, China

Booth:

N3B56

Reservation Form

Reserve Event

Event:

Date and time:

21-23 April 2026 09:00am - 17:00pm

Add:

Algiers exhibition center – SAFEX (Central Hall)

Booth:

B04 (224)

Reservation Form