Contact us

HTY-FT100

Filter Integrity Tester

A filter integrity tester is a testing device that verifies the integrity of filter elements such as filter cartridges and filter membranes using a non-destructive method.

Widely used in industries such as pharmaceuticals, bioengineering, and food and beverage.

Versatile Testing Modes

High Testing Efficiency

Data Compliance

Features

  • Versatile Testing Modes: Supports Bubble Point, Forward Flow, Water Intrusion, Combined Forward Flow & Bubble Point, and Pressure Hold, meeting diverse filter integrity verification needs.
  • High Testing Efficiency: Powered by high-precision sensing technology and intelligent prediction algorithms, it delivers fast and reliable results while significantly reducing test duration.
  • User-Friendly: 10-inch color touchscreen with Windows OS, one-click testing, and multitasking capability.
  • Flexible Options: Optional needle or thermal printer, supports multiple communication protocols such as OPC-UA and Modbus TCP, adaptable for both online and offline use.
  • Data Compliance: 4-level user access control with GMP-compliant audit trail, supports dual-level approval,e-signatures, and data encryption.
  • Reliable Design:  IP54 for dust and splash resistance, modular hardware architecture and redundant safety mechanisms.

Specifications

Weight 12kg
Input Voltage (100-240)VAC
Input Frequency 50/60Hz
Input Power 125W
Fuse Blown <5A
Dimensions 420mm×330mm×265mm
Dperating Temperature (5~50)℃
Storage Temperature (-10~60)℃
Ambient Humidity ≤85%RH,non-condensing
Test Range (1)Forward Flow:(0.01~1000)mL/min (2)Water Intrusion:(0.01~100)mL/min (3)Bubble Point:(400~8000)mbar (4)Pressure Hold:(100~8000)mbar
Sensitivity (1)Forward Flow:0.01mL/min (2)Water Intrusion:0.01mL/min (3)Bubble Point:50mbar (4)Pressure Hold:1mbar

Compliance

EU GMP Annex 1 for the manufacture of sterile medicinal products, February 2008

GMP: The integrity of the sterilised filter should be verified before use and should be confmed immediately after use by an appropriate method such as a bubble point, diffusive flow or pressure hold test.

US FDA Guideline on Sterile Drug Products Produced by Aseptic Processing, 2004

US FDA: Integrity testing of the filter can be performed prior to process and should be routinely performed post-use.

PDA@ Technical Report 26-2008

Where the claimed purpose of the filter is to sterilize, pre and post filtration integrity tests should be performed. Steps should be taken to ensure that the downstream side of the system remains sterile when perfomming a post sterilization, pre-use integrity test.

Applications

The product can be used for:

1) Disposable filtration system PUPSIT

2) Radiopharmaceutical production

3) Pharmaceutical liquid preparation system

4) Intake pressure recovery system on freeze dryers

Pharmaceutical liquid preparation system

Radiopharmaceutical production

Disposable filtration system PUPSIT

Send Inquiry

Article

News

18/12/2025

A New Chapter in Advanced Materials: Tailin Celebrates Groundbreaking of Strategic Production Base

News

17/12/2025

The Final Guardian of Drug Safety: Ensuring Reliable Vials Sealing and Security

News

21/11/2025

From FDA Warning Letters to New Pharmacopoeia Standards: Where Are the Boundaries of “Complete” Microbial Data?

News

04/11/2025

Tailin Honored as “Advanced Committee Unit for Standardization Work” for Supporting Domestic & International Sterilization Standardization

EN

CN

Reserve Event

Event:

Date and time:

30 June - 2 July 2026 09:00am - 18:00pm

Add:

KoelnMesse Halls 7+8, Cologne, Germany

Booth:

Hall 7, N21

Reservation Form

Reserve Event

Event:

Date and time:

16-18 June 2026 09:00am - 18:00pm

Add:

Shanghai New International Expo Center, Shanghai, China

Booth:

N3B56

Reservation Form

Reserve Event

Event:

Date and time:

21-23 April 2026 09:00am - 17:00pm

Add:

Algiers exhibition center – SAFEX (Central Hall)

Booth:

B04 (224)

Reservation Form