Contact us

PBL Series

Sterile Pass Box

The PBL Series Sterile Pass Box (decontamination airlock) is equipped with an integrated Vaporized Hydrogen Peroxide (VH2O2) system for surface decontamination. It features vertical laminar airflow and maintains a Class A internal environment. Controlled by a SIEMENS PLC, the system operates automatically and unattended once sterilization parameters are set.

Vertical laminar Flow

Integrated Vaporized Hydrogen Peroxide sterilization system

Different size can be customized

Features

  • Using VH2O2 102/202 as a biological decontaminant, maintaining a low temperature and normal pressure during the decontamination process, which is efficient and environmentally friendly.
  • Real-time monitoring of temperature, humidity, and pressure.
  • Provides a complete 4Q programme with on-site validation.
  • Meet FDA 21 CFR Part 11 requirements.
  • H14 HEPA filter system.
  • Pneumatic interlock door.
  • Pneumatic sealed door with toughened glass in stainless steel frame.
  • Vertical laminar flow, Class A interior.

Specifications

Air flow: Vertical laminar flow Cleanliness: GMP Grade A
Complete Cycle Time: 150min VH2O2 Residue: ≤1ppm
HEPA Filters: H14 Outlet: 4" or 6" TC
VH2O2 Inlet: 1.5" TC Sterility Assurance Level: ≥6-log kill
Chamber Material: SUS316L Print: Bio-decontamination cycle parameter saving and printing
Alarms: High/low pressure alarm, interlock alarm, VH2O2 concentration alarm,temperature alarm, door open timeout

Applications

For transferring materials such as APIs and tools from low grade areas to Class B areas.

For the handling of items that cannot endure high temperatures into Class A/B aseptic areas.

Pharmaceutical Industry

Biotechnology Industry

Food and Beverage

Send Inquiry

Article

News

18/12/2025

A New Chapter in Advanced Materials: Tailin Celebrates Groundbreaking of Strategic Production Base

News

17/12/2025

The Final Guardian of Drug Safety: Ensuring Reliable Vials Sealing and Security

News

21/11/2025

From FDA Warning Letters to New Pharmacopoeia Standards: Where Are the Boundaries of “Complete” Microbial Data?

News

04/11/2025

Tailin Honored as “Advanced Committee Unit for Standardization Work” for Supporting Domestic & International Sterilization Standardization

EN

CN

Reserve Event

Event:

Date and time:

30 June - 2 July 2026 09:00am - 18:00pm

Add:

KoelnMesse Halls 7+8, Cologne, Germany

Booth:

Hall 7, N21

Reservation Form

Reserve Event

Event:

Date and time:

16-18 June 2026 09:00am - 18:00pm

Add:

Shanghai New International Expo Center, Shanghai, China

Booth:

N3B56

Reservation Form

Reserve Event

Event:

Date and time:

21-23 April 2026 09:00am - 17:00pm

Add:

Algiers exhibition center – SAFEX (Central Hall)

Booth:

B04 (224)

Reservation Form